BREAST MRI / LLM AGENT
Evaluating Neoadjuvant Efficacy in Breast Cancer with Large-Model Agents: Evidence Chains, Tool Calls, and Responsibility Boundaries
Assessing the efficacy of neoadjuvant treatment in breast cancer has long relied on physicians manually selecting slice by slice and measuring the longest diameter by hand, while dedicated segmentation models are constrained by annotation volume and generalizability. This article reviews the technical pathway for using large language model agents to perform segmentation and quantification, discusses how imaging, pathology, and medical records form an evidence chain, how tool calls and structured outputs can control hallucinations, and how evaluation benchmarks and clinical responsibility boundaries should be defined.
In neoadjuvant treatment for breast cancer, the standard way to assess efficacy is to measure the longest diameter of a target lesion. Yet this has always been done manually: physicians select slices and draw lines by hand on contrast-enhanced MRI scans taken before and after treatment. Dedicated segmentation models can automate the process, but they require extensive annotation and may lose accuracy when the equipment changes. Another pathway that has emerged in recent years is to use a large language model agent to orchestrate the workflow: the physician provides a point and a fixed prompt, and the model parses the instruction, calls tools, and performs segmentation and measurement. This approach works, but it solves a workflow problem rather than a diagnostic problem. Clarifying boundaries matters more than making the metrics look impressive.
1. The Real-World Workflow and Three Bottlenecks in Neoadjuvant Efficacy Assessment
The goal of neoadjuvant treatment is to reduce tumor stage, improve the chances of breast conservation, and observe the tumor’s sensitivity to the drugs. Assessment is usually scheduled at baseline, after two to four treatment cycles, and before surgery. Imaging is primarily dynamic contrast-enhanced MRI, with the longest diameter of the target lesion measured and then classified according to RECIST 1.1 as complete response, partial response, stable disease, or progressive disease. It is important to emphasize that radiological response is not equivalent to pathological complete response: residual disease seen on imaging may be fibrosis, while an apparently clean scan may conceal microscopic lesions. The gap between the two determines the subsequent surgical scope.
The bottlenecks in the manual workflow are quite specific. Physicians must select the largest lesion cross-section on each of the two examinations, draw lines in the same direction, and, when lesions are multifocal or irregular, decide which one counts as the target lesion. If the slices or directions are inconsistent before and after treatment, even a deviation of a dozen degrees can make the measured difference exceed the true change. For patients with multiple lesions, only the representative target lesion is measured, while the others are described in text; if a different physician performs the follow-up, the baseline may be reinterpreted. These biases do not appear in the report; they appear only in adjustments to the treatment plan. Recording the measurement direction and slice in the report is the least costly corrective measure.
The difficulty with dedicated segmentation models lies in the data. Training a usable lesion segmentation network requires case-by-case contouring, which is expensive. Models trained on single-center data can lose accuracy when the equipment, contrast-enhanced protocol, or slice thickness changes, and model updates require revalidation. The foundation-model approach seeks to bypass this step, but the cost shifts to prompt design and workflow constraints. Annotation costs may fall, but the engineering constraints do not disappear. For departments with limited resources, whether this trade-off is worthwhile depends on case volume and the scale of follow-up. Departments with fewer cases may find that the marginal cost of maintaining a dedicated model is actually higher.
2. Why Use an Agent Instead of Training Another Segmentation Model
A publicly reported academic presentation described a small-sample study: approximately 100 patients were included, excluding those with radiological complete response or no measurable residual lesion. Six cases were used to develop the prompts, while the remaining 94 cases, totaling 188 examinations, formed an independent test set. The workflow was for physicians to select the largest lesion cross-section before and after treatment and provide point prompts. A fixed prompt guided the model in interpreting the scale and point coordinates, followed by adaptive region thresholding and morphological processing, producing a mask and calculating the longest diameter. Across the entire chain, the model was not retrained; only the organization of inference changed.
Compared with dedicated models, this approach does not update the weights of the segmentation network. What changes is the orchestration during inference: the model understands instructions, breaks down steps, and calls deterministic image-processing tools. The upper limit of segmentation performance is still determined by the foundation model, but removing annotation and training means that adaptation to new diseases or new sequences can be reduced from months to days. For radiology departments, this difference is more attractive than a Dice score one or two points higher, because it directly determines whether the tool can keep pace with clinical workflows. Workflow timing is a practical concern in radiology: a new sequence is often given only a few weeks of preparation time.
The trade-offs must be stated clearly. The workflow depends on manual slice selection and point prompts, so it is not fully automatic. Changes in prompt wording may alter the output, and lesions that are multiple, discontinuous in signal, or poorly delineated are prone to being missed. The study itself reported a failure case in which intratumoral signal discontinuity led to incomplete segmentation, and it explicitly noted that complex lesions still require manual review. Documenting these limitations in the system description builds more trust than avoiding them in demonstrations, and it determines how physicians will use the system after deployment. If the description lists only capabilities and omits limitations, physicians will lose trust at the first failure.
3. Multimodal Evidence Chain: How Imaging, Pathology, and Medical Records Corroborate Each Other
Imaging evidence is the primary chain. Dynamic contrast-enhanced MRI provides lesion size, morphology, enhancement pattern, and time-signal curve; a decrease in enhancement after treatment usually suggests response. Fibrosis, necrosis, and inflammatory changes, however, can also alter enhancement, so imaging alone has limited sensitivity for determining pathological complete response. Ultrasound and mammography can provide supplementary information, although they have limited value for deep lesions and dense breast tissue and are mainly used for accessibility and follow-up convenience. The real role of imaging is to clearly describe the lesion’s location, extent, and change over time, providing context for the pathological conclusion. Imaging cannot replace pathology, but it can clearly establish where the lesion is and how extensive it is.
Pathological evidence is the gold standard, but it comes from two time points. Pretreatment biopsy specimens provide hormone receptor status, HER2 status, and proliferation index, which determine whether anti-HER2 therapy or platinum-based treatment should be added. Post-treatment surgical specimens provide Miller-Payne grading or residual tumor burden grading, which are the final criteria for efficacy. If a patient refuses surgery after downstaging or cannot undergo surgery, the gold standard is missing. Such missing data are not random and must be flagged separately during analysis. Managing pathological information from the two time points separately prevents pretreatment subtypes from being used to explain post-treatment residual disease.
Medical record evidence determines attribution. Treatment regimen, number of cycles, dose adjustments, adverse reactions, menstrual status, and prior treatment history all affect the interpretation of imaging changes. The same reduction in lesion size means something entirely different after a full course of treatment versus a mid-course dose reduction. Structuring these fields makes it possible for the model to cite evidence when presenting conclusions instead of simply outputting a number. The value of medical record fields becomes most apparent when there is a conflict: without them, physicians can only rely on memory when imaging and pathology disagree. Aligning treatment schedules with imaging time points is the easiest step to skip in an evidence chain.
The real value of an evidence chain lies in conflict detection. Imaging may show clear response while pathology still shows residual disease, or imaging may show persistent abnormal enhancement while pathology indicates complete response. Both situations are not uncommon clinically. The system should flag conflicts, provide uncertainty, and suggest a review action rather than forcing a grade. A system that can recognize when its evidence is insufficient is safer than one that always provides a definitive answer, and it better matches clinical expectations for assistive tools. Clinicians are more willing to accept a system that says it does not know than one that is always confident. Building this attitude into interaction design is more effective than placing it in training materials.
4. Tool Calls and Structured Outputs: Turning Language into Auditable Fields
Start with coordinate parsing. Points, scales, and units in prompts must be converted into pixel coordinates, while the image orientation matrix, slice number, and geometric differences between sequences must also be handled. Unit errors are the most common basic failure: treating millimeters as centimeters makes the longest diameter differ by an order of magnitude, while the report appears normal. From an engineering perspective, unit conversion should be hardcoded in the tool rather than left to the model’s discretion. The parsing result should also be echoed back to the physician so that errors can be discovered during parsing. Echoing the result can also expose problems in the prompt itself, which is more intuitive than checking logs afterward. When the parsing result is stored, the original prompt text should be recorded as well.
Next come thresholding and morphology. Adaptive region selection, connected-component analysis, and opening and closing operations determine how well the mask fits the boundaries. Parameters must be fixed and reproducible; otherwise, two runs on the same case may produce different results, making repeatability impossible to discuss. Parameter changes must go through a versioning process, and the fixed regression cases must be rerun to confirm that previously correct segmentations have not been broken. This process may look cumbersome, but it prevents a model upgrade from disrupting historical follow-up data. The parameter set should be frozen as a configuration file and archived with the model version. Separating the configuration file from the code makes rollback possible without redeployment.
The output must be structured into fields. Lesion location, slice, area, longest diameter, confidence, tools and parameters called, and failure reason should all be stored as queryable records rather than a paragraph of natural-language description. Only after structuring can the data be ingested, audited, and linked to pathology and follow-up; only then can downstream statistical and quality-control scripts consume the data directly without relying on humans to read reports. Field definitions should be aligned with clinical stakeholders at the start of the project, because changing fields later costs far more than discussing them upfront. Field naming should avoid synonym duplication, otherwise downstream linkage will produce many unmatched records.
Finally, there is run consistency. Running the same input twice, the mask consistency and the difference in longest diameter should serve as quality gates. If the difference exceeds a threshold, the result should be marked as unstable and referred for manual review. This action costs little, but it prevents most errors caused by randomness and is also necessary for incorporating generative systems into routine quality control. If the two results differ greatly, it indicates ambiguity in the prompt or the image itself; the correct action then is to roll back and review rather than average the results. Consistency-check records are themselves evidence of when the system is unreliable. The quality-gate thresholds must be written into acceptance criteria rather than decided at the last minute.
5. Where Hallucinations Come From and How to Suppress Them
Hallucinations generally fall into three categories. One is fabricated lesions: finding a region on a slice with no clear lesion, especially in areas of postoperative change, metal artifacts, or dense glandular tissue. Another is numerical drift: choosing the wrong direction, applying the wrong unit conversion, or treating area as diameter, causing values to differ by orders of magnitude. The third is textual fabrication: inventing prior treatment history, fabricating comparison results, or writing uncertain judgments as definitive conclusions. The causes differ, so the countermeasures cannot be mixed up. Fabricated lesions are addressed through retrieval and refusal; numerical drift through tool constraints; textual fabrication through field-based output.
Mechanistically, the issue is not mysterious. A language model generates output rather than measures it; as soon as it is asked to state numbers directly, fabrication is possible. The suppression strategy is to assign quantification to deterministic tools, leaving the model to parse instructions, select tools, and organize output. Output should be limited to enumerated values and numerical fields, with supporting evidence required, such as coordinates, slice numbers, and tool return values. Conclusions without evidence should not be accepted. These constraints sacrifice some flexibility but deliver auditability. In clinical settings, auditability matters more than flexibility because conclusions must be reviewable.
A refusal mechanism is also necessary. When image quality is poor, a lesion is discontinuous, a prompt point falls outside the lesion, or a reference sequence is missing, the system should report a failure rather than force a result. During acceptance testing, trap sets should be constructed specifically: cases without lesions, postoperative changes, bilateral lesions, metal artifacts, and extreme body types. Performance on trap sets is more informative about reliability than performance on ordinary test sets because it tests whether the model fabricates when information is insufficient. Trap sets should be expanded periodically, and newly observed failure types should be added as early as possible. The expansion cycle can be aligned with the model versioning cycle.
6. Evaluation Benchmarks: Segmentation, Measurement, and Classification Should Be Assessed Separately
At the segmentation level, look at Dice and success rate. The study mentioned above reported a Dice of approximately 0.9 and defined segmentation success as Dice greater than 0.5, with a success rate close to 99%. The two figures need to be read together to have meaning: the success rate is sensitive to the threshold, and a lower threshold naturally produces a higher success rate. A fuller report should also include surface-distance distributions and the specific shapes of failed cases; otherwise, readers cannot determine where failures concentrate. Metrics are compressed results, and compression loses information, so the report must restore what was discarded. Reporting only a single mean does not allow readers to assess performance on difficult cases.
At the measurement level, look at consistency and bias. The study reported an intraclass correlation coefficient of approximately 0.985 between the longest diameter and the reference standard, with an average bias of approximately 1.7 mm in the positive direction, indicating a slight systematic overestimation. This magnitude is clinically acceptable, but it should be recognized when making follow-up comparisons. Bland-Altman limits of agreement should also be provided rather than only a correlation coefficient, because a high correlation coefficient does not mean a small bias. The report can include a scatter plot showing how bias changes with lesion size; bias is usually greater for small lesions.
At the classification level, look at the confusion matrix. In the study, F1 scores for partial response and stable disease were approximately 0.92 and 0.85 respectively, and progression cases were also identified relatively well. However, the sample size was small and the confidence intervals were wide. More importantly, the study excluded radiological complete-response cases, effectively removing the easiest negative cases to classify and thereby overestimating classification performance. When reading such results, examine the inclusion and exclusion criteria first, then the metrics. With only a few dozen cases, a single case can shift the F1 score by several hundredths. Reporting confidence intervals is not mere formalism; they directly determine how far the conclusions can be extended.
| Evaluation Dimension | Common Metrics | Common Pitfalls |
|---|---|---|
| Segmentation | Dice, surface distance, success rate | Success rate varies with the threshold; the definition must be stated |
| Measurement | ICC, Bland-Altman, average bias | A high correlation coefficient does not mean a small bias |
| Classification | F1, confusion matrix, sensitivity | Excluding complete responses overestimates performance |
| Reproducibility | Dice and ICC across two runs | A single best result does not indicate stability |
| Efficiency | Time per case, number of manual interventions | Reporting only model time omits the cost of slice selection |
7. Clinical Responsibility Boundaries and Regulatory Pathway
The positioning must be made clear from the start: this is an assistive tool. Outputs are references for physician judgment; signing and decision-making remain with clinicians. A two-dimensional measurement of a single target lesion cannot replace a complete RECIST assessment, which also involves summing multiple lesions, measuring short-axis lymph nodes, evaluating non-target lesions, and identifying new lesions. Stating the scope of application at the beginning of the product instructions reduces misuse more effectively than placing it in an appendix. The easier a tool is to use, the more likely it is to be used beyond its intended scope. Clear boundaries protect physicians and the system itself. The more specific the scope of application, the lower the training cost and the lower the probability of misuse.
Regulatorily, such systems are managed as software medical devices and require a clearly defined intended use, intended population, conditions of use, and failure modes. Conditions of use are especially important: whether a physician must select slices, whether point prompts must be provided, and which sequences and field strengths are supported all change the risk profile. Whether upgrades to a foundation model or major changes to prompt templates constitute significant changes should be discussed with regulators in advance rather than explained after deployment. Version management and change assessment should be part of product design. Change assessments must leave written records; otherwise, it will be impossible to explain what changed during the next audit.
Responsibility allocation depends on records. If a segmentation error leads to a misjudgment of treatment efficacy, how responsibility is shared depends on the system’s positioning, warnings in the instructions, and records of manual review. Audit logs, model versions, prompt-template versions, input-sequence lists, and reviewer signatures become important only when a dispute arises. The technical team should treat them as part of the product during the design phase rather than adding them afterward. The value of records is not to assign blame, but to ensure that every judgment can be traced and reviewed. Log retention periods should align with medical-record retention requirements; anything shorter is effectively equivalent to no retention.
8. Data and Annotation Engineering: Pairing, Reference Standards, and Follow-Up Linkage
Pairing is the foundation of this kind of research. The correspondence of the same lesion before and after treatment, differences in slice thickness and patient positioning, and deformation caused by respiration and movement all affect measurement. If pairing is wrong, every subsequent metric becomes meaningless. A practical approach is to make the pairing relationship an independent field confirmed by physicians, rather than inferring it automatically from file names or examination dates. Automatic inference can be used for preliminary screening, but a final manual pass is still required. Once pairing is established, registration residuals should be recorded as the basis for later bias interpretation. Pairing errors are common in retrospective data, especially in cases with multiple examinations and multiple lesions.
Reference standards are usually created by fusing independent contouring by two physicians, with disagreements resolved by a third-party adjudicator. It is important to recognize that the reference standard itself has error: if the Dice score between the two physicians is only 0.85, then a model achieving 0.9 is already close to the ceiling, and pursuing additional points has limited value. The research report should provide inter-physician consistency as a background value so readers can judge where the model stands. The construction method of the reference standard should also be clearly described, because different fusion algorithms can produce noticeable differences. If the physicians’ disagreement is concentrated at the boundaries, that is also where the model’s upper limit stops.
Follow-up linkage determines long-term value. Pathological complete response comes from surgical specimens and is the hardest gold standard; event-free survival and overall survival require longer follow-up periods. Only by linking imaging, pathology identifiers, surgery dates, and treatment regimens into a queryable record is retrospective validation possible. Many institutions have the data but cannot link it, often because they lack a unified patient master index and consistent field definitions. There is no shortcut; each field must be aligned one by one. Without a unified patient master index, all subsequent linkage becomes manual work. Field alignment should be moved forward into the data-collection stage.
9. Implementation Path: From a Single Target Lesion to 3D and Multiple Lesions
The starting point is two-dimensional assessment of a single target lesion, which is currently the scenario with the strongest evidence. Its boundaries are clear: the physician selects the slice, provides the point, the system measures, and the physician reviews. It is suitable to begin with parallel operation on an internal network, comparing results with manual measurements for three months to confirm the distribution of bias and types of failures before expanding the scope of use. The parallel-phase dataset is itself the most valuable local validation set, closer to the institution’s equipment and workflows than any public data. The goal of the parallel phase is to discover failure modes, not to prove that the system is faster than humans. If failures occur frequently during the parallel phase, the chosen scenario is too broad.
The second step is three-dimensional assessment. Three-dimensional measurement must handle interslice inconsistency, anisotropic voxels, and lesions extending across slices, making the difficulty significantly higher. For irregular lesions, the clinical interpretation of three-dimensional diameters has not yet been fully standardized. Technical feasibility does not mean the evaluation framework is ready; radiology and clinical departments must jointly define what constitutes an acceptable deviation. Until a consensus is reached, three-dimensional results are better used as reference information than written directly into efficacy conclusions. The real threshold for three-dimensional assessment is the evaluation standard, not the algorithm itself. Until the standard is set, treat three-dimensional results as internal references.
The third step is multiple lesions and multiple modalities. Summing multiple target lesions, measuring short-axis lymph nodes, and providing qualitative descriptions of non-target lesions must all be incorporated into the workflow. Only after pathology and medical-record fields are connected can an evidence chain be established. Every expansion increases validation cost, so progress should be made gradually by disease type and scenario rather than building a universal platform all at once. A universal platform sounds convenient, but it often fits none of the scenarios well and eventually requires customization. Advancing by scenario is slower, but every step leaves a verifiable record. Being slower is acceptable as long as every step can be reviewed.
10. Forward-Looking Assessment for the Next 12 to 24 Months
Over the next one to two years, foundation models will offer more mature support for three-dimensional and multi-sequence inputs, and it will become routine to hand an entire image volume and multiple sequences directly to the model. Prompt engineering will become less important, replaced by toolchains and evaluation sets. Whoever can make coordinate parsing, threshold processing, unit checking, and failure rollback robust will have the more stable system. This change is good news for engineering teams, but not for teams that only know how to tune prompts. Evaluation-set quality will gradually become a major variable that distinguishes products. If evaluation sets use only public data, they will struggle to reflect differences in local equipment and protocols.
Research endpoints will shift from segmentation accuracy to whether decisions change. Measurement time, inter-observer consistency, net benefit from efficacy classification, and the proportion of treatment plans adjusted because progression was identified early will gradually replace simple Dice competitions. When screening the literature, readers can look first at endpoint definitions, then sample size and inclusion/exclusion criteria, and only afterward at metric values. If the endpoint is wrong, even a large sample cannot answer the clinical question; this is already common in the medical imaging AI literature. Once the endpoint is clearly defined, sample size becomes meaningful; otherwise, the numbers are merely impressive-looking.
Regulators will remain cautious about continuous learning, and version freezing will remain the mainstream practice. When hospitals procure systems, local validation, audit logs, and failure-rollback mechanisms will be prerequisites rather than optional features. For vendors, the ability to provide reproducible validation reports matters more than the ability to demonstrate an attractive case. For hospitals, the ability to run validation independently determines bargaining room. These two realities will become clearer over the next two years and will filter out proposals that are only capable of demonstrations. Procurement leverage ultimately comes from whether the hospital can reproduce the results itself. Validation capability is becoming a basic institutional capability for hospitals.
The first beneficiaries will be two types of institutions: centers with paired pre- and post-treatment imaging and pathological gold standards, and radiology departments whose MRI protocols have already been standardized. The former can produce credible external validation, while the latter can keep systems stable across different devices. Institutions that meet neither condition will struggle to prove a tool is effective even if they buy one. The implication for procurement decisions is direct: examine the data foundation first, then the feature list. Reverse the order, and you are likely to buy an expensive demonstration that is difficult to validate. This order looks simple but is often reversed in practice.
11. Conclusion: Take Over Repetitive Work, Leave Judgment to Humans
The value of agents in efficacy assessment is to take over repetitive, drift-prone measurement tasks and give physicians more time for judgment. They do not solve diagnostic problems or change the basic framework of efficacy evaluation; what they change is how work is executed and recorded. Recognizing this prevents overpromising during demonstrations and prevents wholesale rejection when failures occur. Once the technical positioning is clear, validation design and responsibility allocation have a basis for discussion. A system with an ambiguous positioning is often treated as a universal tool and then quickly abandoned. The value of a tool is ultimately reflected in how long it can be used reliably.
Engineering teams must accept constraints: two dimensions, a single target lesion, dependence on manual slice selection, and point prompts. Writing these limitations into the instructions is safer than hiding them. What truly deserves investment is the failure-mode catalog, refusal rules, and audit records, rather than packaging the model as omnipotent. Clinical trust comes from predictable behavior, not occasional impressive performance. A system that produces similar results every time and clearly explains its failures is easier to accept than one that occasionally performs exceptionally. Stability is the prerequisite for clinical trust; occasional brilliance can instead raise doubts. Making stability part of the acceptance metrics is more persuasive than emphasizing capabilities.
Investment on the data side has the highest return. If pairing relationships, reference standards, and links between pathology and follow-up are handled well, any model will benefit; if they are not handled well, even a stronger model will only produce a collection of unexplained numbers. For teams preparing to enter this area, I recommend spending two months building the data foundation before discussing model selection. Models change; the data foundation does not. It is the long-term asset. Once the foundation is built, changing models is simply replacing a component rather than redoing the project. With the foundation in place, the team will have the capacity to address workflow issues beyond the model itself.
Langhui's Engineering Capabilities Along This Path
Since 2016, Langhui Technology has focused on AI training data. In medical imaging, its coverage includes CT, MR, PET, mammography, ultrasound, and other modalities. Services include acquisition-specification design, structured annotation, quality-control workflows, and consistency reports. For breast projects, we first align fields such as sequence, slice thickness, contrast-enhanced protocol, and treatment time point with clinical stakeholders before defining annotation standards for lesion boundaries, target-lesion selection, and follow-up pairing.
For annotation execution, we use independent dual contouring followed by arbitration, calculate consistency separately at the detection, boundary, and measurement levels, and issue reports containing disagreement matrices and bias distributions. Annotation manuals, data dictionaries, and version records are delivered with each batch so that every sample can be reviewed and traced. Pathological and follow-up conclusions are provided by partners according to specifications; we are responsible for linkage, missing-value marking, and field validation.
If your team is building a paired imaging dataset for neoadjuvant efficacy assessment, or needs evaluation sets and trap sets for an agent workflow, you can send us the modality combinations, lesion types, inclusion and exclusion criteria, and follow-up fields. We will provide actionable acquisition and annotation recommendations and finalize the scale-up criteria after a small-batch trial annotation.
FAQ
Do I need to train my own model to perform lesion segmentation with a large model?
No. On this technical pathway, segmentation is performed by a foundation model in conjunction with prompts and tools. The team’s work involves prompt-template design, coordinate and unit validation, threshold and morphological parameter settings, and failure rollback. Annotation and training can be omitted; local validation and quality control cannot. If lesion types are unusual or image quality is poor, a dedicated model may still be needed as a fallback.
Can a segmentation Dice score of 0.9 replace physician contouring?
No. A score of 0.9 is the result of comparison against a reference standard, and that reference standard is itself created by fusing physician contours, with inter-physician variation. More importantly, Dice does not reflect directional bias in the longest diameter or the distribution of failed cases. The appropriate positioning is assistive measurement and preliminary screening; final contouring and judgment must still be performed by physicians, especially in cases with multiple lesions, unclear boundaries, or marked post-treatment changes.
Why were patients with radiological complete response excluded from the study?
Because such cases have no measurable residual lesion, cannot be evaluated using the longest diameter, and are unsuitable for segmentation tasks. After exclusion, the study can only describe performance in populations with measurable lesions and cannot be generalized to complete-response populations. Readers should keep this in mind: the exclusion makes classification performance appear better because the easiest negative cases to classify were removed.
Could an agent fabricate the longest-diameter value?
It could if the model is allowed to generate numbers directly. The controllable approach is to assign measurement to deterministic tools: the model parses only coordinates and parameters, the image-processing tool outputs the mask and longest diameter, and the model then places the result into fixed fields. Slice number, coordinates, and tool return values should also be required as evidence, with a consistency check across two runs; if the difference is too large, the case should be referred for manual review.
Can this workflow be used directly for a complete RECIST efficacy assessment?
Not at present. Most studies evaluate only the two-dimensional longest diameter of a single target lesion, while complete RECIST also requires summing multiple lesions, measuring short-axis lymph nodes, evaluating non-target lesions, and identifying new lesions. A complete assessment requires multi-lesion tracking, organ compartment definitions, and follow-up time windows to be incorporated into the workflow, followed by validation with larger samples and multiple centers. For now, it is more appropriate to position the system as assistive measurement for a single target lesion.
- Eisenhauer et al., New response evaluation criteria in solid tumours: revised RECIST guideline (version 1.1) https://pubmed.ncbi.nlm.nih.gov/19097774/
- Singhal et al., Large language models encode clinical knowledge (Nature) https://www.nature.com/articles/s41586-023-06291-2
- World Health Organization, Ethics and governance of artificial intelligence for health: large multi-modal models https://www.who.int/publications/i/item/9789240084759
- U.S. FDA, Artificial Intelligence and Machine Learning (AI/ML) Software as a Medical Device https://www.fda.gov/medical-devices/software-medical-device-samd/artificial-intelligence-and-machine-learning-software-medical-device
- Wang et al., A Survey on Large Language Model based Autonomous Agents https://arxiv.org/abs/2308.11432
- Cardoso et al., MONAI: An open-source framework for deep learning in healthcare https://arxiv.org/abs/2211.02701