Langhui

RADIOMICS / REPRODUCIBILITY

Reproducibility of Radiomics Toolchains: IBSI Standards, Feature Drift, and Comparison of Open-Source Tools

The most common point of failure in radiomics is not the model architecture but the entire pipeline from scanning protocol to parameter configuration. This article covers what the IBSI standard can and cannot govern, the two hidden switches of resampling and gray-level discretization, how inter-batch drift amplifies into conclusion drift, trade-offs in open-source tools such as PyRadiomics, and reporting checklists and data version management, offering actionable acceptance criteria.

Healthcare & MedicineLanghui Industry Research · R&D Exchange Notes

Radiomics is one of the few fields where you can produce a paper by installing an open-source package, and also one of the few that pays a price for it. Swap the same dataset to a different scanner, a different software version, or a different person's contouring, and the conclusions can flip entirely. Reproducibility is not academic fussiness; it is the precondition for this pipeline entering clinical practice. This article does not discuss which model is more advanced. It addresses one question: when someone claims to have obtained results using radiomics, how do you judge whether others can reproduce those results, and what needs to be recorded to do so?

1. Why producing results and reproducing results are two different things

The barrier to entry for radiomics is dangerously low. Install an open-source package, load a set of sequences, contour a region of interest, and run it with default parameters, and you can output thousands of features and a set of seemingly good areas under the curve. The real trouble starts with the next step: swap the same dataset to a different scanner, a different software version, or a different person's contouring, and do the conclusions still hold? Reproducibility discussions are especially sharp in radiomics, and the reason is simple: there are too many undocumented defaults in this pipeline.

Between producing results and reproducing them lie three types of information: how the data came to be, how the parameters were set, and how the conclusions were calculated. The first includes scanning protocols, reconstruction kernels, slice thickness, and contrast agent phases; the second includes resampling spacing, bin width or number of bins for gray-level discretization, and filters; the third includes the order of feature selection, how cross-validation splits were made, and how thresholds were chosen. If any link is not documented clearly, others can only guess.

A more common scenario is that a paper states the software name and version but omits the parameter file, or states that default settings were used without noting that defaults changed between versions. Such omissions will not cause a paper to be rejected, but they will cause subsequent replication studies to fail. After the failure, authors often attribute the cause to data differences rather than missing documentation, so the same trap is stepped into repeatedly.

To judge whether a paper is reproducible, there is a simple but effective method: find someone who was not involved in the project and ask them to attempt to rerun it based solely on the methods section. If they get stuck more than three times within two hours, the description is inadequate. This test is imperfect, but it is closer to reality than any self-assessment.

Schematic of the radiomics pipeline: acquisition protocol, region-of-interest contouring, resampling and discretization, feature extraction, selection and modeling, external validation, and the scope covered by IBSI
Fig.1 IBSI mainly covers consistency in feature definitions and preprocessing; acquisition protocols and modeling validation still need to be handled by the research team. If the two ends of the chain fail, no amount of standardization in the middle will make the work reproducible.

2. What the IBSI specifies, and what it does not

What the Image Biomarker Standardisation Initiative (IBSI) does, in essence, is turn features from ad hoc formulas into objects with unified definitions, reference values, and a validation process. It provides the mathematical definition of each feature, recommended preprocessing steps, and a set of digital phantoms and reference values for checking whether a software implementation conforms to the definition. For anyone conducting multicenter research, this is currently the closest thing to a common language.

But IBSI is not a cure-all. It specifies how a feature is calculated, not which feature you should use; it does not specify scanning protocols, who should contour the region of interest, or how statistical models should be built. In other words, IBSI ensures that numerical values computed by different software on the same dataset can be matched, but whether two datasets from different hospitals are comparable still depends on acquisition and preprocessing. This point is often misunderstood.

There is also a gap in practice: an IBSI-compliant implementation requires feature-by-feature validation, which is labor-intensive, and many tools only cover a subset of categories. Some software claims to follow IBSI but has actually only validated a few features. If researchers treat it as a binary pass/fail label, they are prone to over-trusting it.

A more practical approach is to treat IBSI as a dictionary of feature definitions and a ruler for acceptance, not as a quality standard in itself. At minimum, do two things during acceptance: first, run a public digital phantom and check deviations in key features; second, run the same dataset through two implementations and check whether the rankings are consistent. Only after completing both can you say the pipeline is sound.

Schematic of the relationship between resampling and gray-level discretization parameters: fixed bin width, fixed number of bins, gray-level range clipping, interpolation method, and paired recording requirements
Fig.2 Resampling changes voxel size, which changes gray-level variance and in turn changes the proportion of voxels in each bin after discretization. Adjusting a single parameter is equivalent to swapping in a different feature definition.

3. Resampling and gray-level discretization: two hidden switches

Resampling spacing determines how much physical size a voxel represents. Slice thickness and reconstruction field of view vary across devices, so the number of voxels representing the same lesion can differ substantially across datasets. Resampling anisotropic voxels onto an isotropic grid is standard practice in most pipelines, but choosing 1 millimeter or 2 millimeters spacing directly changes texture feature values, especially for gray-level co-occurrence matrix features.

Gray-level discretization is the second hidden switch. Fixed number of bins and fixed bin width strategies yield very different results when lesions have widely varying gray-level distributions. A fixed number of bins forcibly flattens the relative quantization of different lesions, while a fixed bin width produces too few gray levels for lesions with narrow gray-level ranges. The choice must match the data type and research question, and it must be stated in the methods.

These two parameters also interact: increasing resampling spacing averages voxels and reduces the variance of the gray-level distribution; discretizing with a fixed bin width under these conditions changes the proportion of voxels falling into each bin. In other words, adjusting one parameter alone is not valid; they must be recorded together. Many replication failures stem precisely from these two parameters not being reported jointly.

In practice, a simple approach is to package resampling spacing, interpolation method, discretization strategy, and gray-level range clipping into a single configuration object, archive it with the experiment, and compute a checksum. This way, any result can be traced back to a specific parameter combination rather than relying on memory. The cost is low, but the benefit spans the entire project lifecycle.

4. How drift in feature parameters amplifies into conclusion drift

A single feature being insensitive to parameters does not mean the feature set is stable. Among thousands of features, there is often a group highly sensitive to resampling and discretization, and another group that is relatively robust. If the selection step does not account for this, the model may well select those sensitive features, performing well at one center and collapsing at another. This failure is not due to the model lacking complexity; it is because the model learned noise.

Even more insidious is the order of selection and validation. A common mistake is to perform feature selection on the full dataset before cross-validation. In this case, information from the validation set has already leaked into the model through the selection step, and the reported performance is systematically overestimated. The correct order is to place selection within the training portion of each fold and repeat the entire process, including normalization and dimensionality reduction, without taking any step out of order.

High correlation among features also amplifies the problem. Radiomics features are commonly correlated in clusters; change one parameter and the ordering within a cluster changes, altering which representative features ultimately enter the model. This is not necessarily an error, but it means conclusions about which features are most important are not stable across parameter settings. If a paper treats feature importance as a biological discovery, extra caution is needed.

An actionable acceptance criterion is stability selection: repeat extraction over a reasonable range of parameter perturbations, compute intraclass correlation coefficients, and retain only features that remain stable under perturbation before proceeding to modeling. This sacrifices some performance, but the payoff is that conclusions do not collapse when the center changes. The trade-off depends on research goals: mechanism exploration and production tooling call for different answers.

5. Inter-batch drift: the impact of equipment, protocols, and reconstruction kernels

Scans from the same device at different times may differ: tube aging, calibration drift, and software upgrades all alter noise characteristics. Across devices, the problem is more pronounced. Reconstruction algorithms from different vendors handle edges and noise differently, and texture features are affected first. These differences are often invisible to the eye but significant in feature space.

The impact of the reconstruction kernel deserves separate discussion. Reconstructing the same raw data with different kernels yields different levels of sharpening and high-frequency information content; entropy and edge-based features shift systematically. If a study spans a change in the institution's reconstruction protocol, the data before and after actually come from two distributions. This is not the model's fault; data management failed to keep up.

There are several layers of mitigation. At the acquisition level, fix protocols as much as possible and specify the reconstruction kernel, slice thickness, and contrast agent regimen in the study protocol. At the data level, perform phantom calibration or use reference tissues for normalization. At the modeling level, use batch-aware normalization or explicitly include samples from multiple devices in the training set so the model has seen such differences. Of the three layers, the first is most effective and most often skipped.

But every correction has a cost. Excessive normalization can erase genuine biological differences, especially when inter-lesion heterogeneity is itself the research objective. A sounder principle is to first quantify how large the drift is, then decide whether to correct it and to what degree, and to report the quantification results. An unquantified correction is essentially a gamble.

6. Open-source tool comparison: PyRadiomics and its neighbors

PyRadiomics is one of the more widely used open-source implementations. Its strengths include a clear interface, broad feature category coverage, smooth integration with image-processing libraries, and the ability to fix parameters via configuration files. Its documentation details each feature's formula and parameter dependencies, which is critical for reproducibility. Researchers should at minimum submit the configuration file alongside the paper rather than merely stating that default parameters were used.

The R ecosystem is closer to statistical workflows; feature extraction packages integrate naturally with modeling and visualization, making them suitable for research centered on statistical inference. Deep learning frameworks occupy a different position: they mainly handle segmentation and end-to-end representation learning, and their outputs are not nameable features but latent vectors. Interpretability and cross-center stability must be assessed separately, and the acceptance criteria for feature engineering cannot be applied directly.

The primary criterion for tool selection is not feature count but whether parameters can be frozen, versions can be traced, and results can be aligned. A tool with fewer features but fixed parameters is more suitable for multicenter research than one with extensive features whose defaults change between versions. There is a trap here: install the latest version, run it, and write that default parameters were used; a year later, someone else may install a different version, and the conclusions naturally will not match.

In practice, a common combination is to use one implementation for feature extraction and another for cross-validation, retaining only features stable across both before modeling. This adds limited cost but can detect implementation-level deviations early, which is far more economical than explaining afterward why a model failed. Newer is not better; the more easily others can install it back, the better.

Tool typePrimary positioningReproducibility concerns
PyRadiomicsPython feature extraction, configuration-drivenConfiguration file, version, feature category coverage
R feature packagesExtraction and modeling within statistical workflowsDependency versions, default parameters, factor handling
Commercial workstationsClinical reading and semi-automatic segmentationUncontrolled versions, opaque parameters, export formats
Deep learning frameworksSegmentation and end-to-end representationWeights, preprocessing, training data distribution

7. Region-of-interest consistency: manual, semi-automatic, and model outputs

The region of interest is the most subjective part of radiomics. Manual contouring is accurate but time-consuming, and there are differences between physicians and within the same physician over time. The definition of peritumoral regions is even more ambiguous: expanding outward by 3 millimeters versus 5 millimeters, and whether to exclude vessels and edema, all change the features. If these choices are not documented clearly, others cannot reproduce the work or determine where differences come from.

An underappreciated advantage of deep learning segmentation is consistency. The model's boundaries on a given case may not be more accurate than an expert's, but its outputs for the same case are deterministic and do not drift due to fatigue or habit. In terms of systematic error, this determinism is sometimes more important than single-pass accuracy, especially when processing hundreds or thousands of cases.

But determinism does not equal correctness. If the model has a systematic bias—for example, habitually shrinking boundaries inward—then all cases will deviate in the same way and the feature distribution will shift as a whole. During modeling, this may be absorbed by the labels, appearing not to affect performance, but it will fail when applied to data from another segmentation model or manual contouring. A bias masked by consistency is a harder class of problem to detect.

A practical approach is to incorporate segmentation quality assessment into the workflow: sample cases for dual-person contouring, compute overlap and boundary distance, and also assess feature-level sensitivity to segmentation perturbations. Reporting segmentation accuracy without feature stability is equivalent to checking only the first half of the pipeline. True acceptance requires seeing whether the feature step remains stable.

8. Reporting checklist: what else needs to be documented beyond IBSI

The methods sections of current radiomics papers generally lack not model details but data and parameter details. It is recommended to write in four blocks: data source and inclusion/exclusion, image acquisition and reconstruction, preprocessing and feature extraction, and modeling and validation. Each block must be documented to the level where others can follow along, rather than a single sentence stating that standard procedures were used. In a reproducibility context, the phrase "standard procedures" is almost equivalent to saying nothing.

Reporting checklist tools provide a skeleton, but they are not purpose-built for radiomics. Radiomics requires additional details: software and version, configuration file, resampling and discretization parameters, specific feature-selection steps, segmenters and segmentation tools, and a statement on the availability of code and data. Among these, the configuration file and selection steps are the two most commonly missing.

There is a practical constraint: imaging data from many hospitals cannot be made public, and code may involve internal systems. Reproducible does not mean data must be public. Alternatives include providing synthetic data, providing parameters and code, and providing feature tables and de-identified intermediate results. The key is to enable third parties to verify the pipeline rather than simply trust the conclusions. The difference between these two states is magnified during both peer review and implementation.

9. Data versions and experiment logs: turning reproducibility into engineering

Data version management is often overlooked in radiomics. Cohorts change: cases are added, labels corrected, ineligible images removed, and follow-up updated. Without recording versions, an experiment from two years ago cannot be reconstructed, because the dataset it corresponds to no longer exists. It is recommended to take a snapshot of each dataset, record the inclusion/exclusion cutoff date, case list, and checksum, and link the snapshot to experimental results.

Experiment logs must also be recorded to files, including random seeds, cross-validation fold assignments, hyperparameter search spaces, and dependency library versions. These are often implicit in scripts and lost once the run is over. A pragmatic approach is to containerize the entire run environment, archive configuration and results together, and make each experiment a replayable unit. Replayability is more reliable than however well the documentation is written.

Another easily overlooked element is the definition and timing of labels. The same recurrence label, defined by radiographic progression versus biochemical markers, yields different results; the same follow-up with different cutoff dates yields different event counts. These definitions must be written into the data dictionary and bound to versions. Otherwise, comparing two models is meaningless, because their dependent variables are not the same thing at all.

10. From single-center to multicenter: how to design reproducibility acceptance

The value of multicenter research lies in testing generalization, but many so-called multicenter studies merely pool data for training and then randomly split the same pool for validation. This is not external validation. True external validation requires that the validation data be independent of the training data in acquisition device, scanning protocol, and patient source, and be used only after modeling is complete, with no backtracking to tune parameters in between.

Acceptance design can be divided into three levels: level one is same-source replication—rerunning the same dataset with a different implementation to check whether the code and parameters are fully specified; level two is cross-center replication—applying a fixed model directly to data from a new center to check generalization; level three is prospective replication—collecting new data over a new time period following a preregistered process. Most studies stop at level one yet write conclusions in the tone of level three; this is the most prevalent gap today.

When accepting across centers, it is recommended to report performance both at the original threshold and after recalibration. The former reflects the model's direct usability; the latter reflects its information content. If performance recovers substantially after recalibration, the model has learned the signal but the distribution has shifted; if it still fails after calibration, the features themselves do not transfer. The remedial measures for these two failures are completely different; mixing them together leads to wrong conclusions.

11. Forward-looking assessment for the next 12 to 24 months

Within the next year, the most certain change is that parameter documentation will shift from voluntary to a threshold requirement. More journals and conferences are explicitly requiring feature extraction configurations and code in submission guidelines, and some will also require feature tables. This will eliminate a batch of vaguely described studies and push the tool ecosystem toward configurations that can be exported and versions that can be locked. For teams, the earlier configuration management becomes habit, the lower the migration cost.

The second change is the standardization of validation. As regulatory requirements for algorithmic evidence increase, simple internal cross-validation will be insufficient for registration filings; multicenter external validation and calibration reports will become routine requirements. The earliest beneficiaries will be institutions that have already built data dictionaries, segmentation standards, and follow-up chains, because they can quickly assemble teams for validation rather than scrambling to find data.

The third change relates to foundation models. End-to-end representation learning will continue to gain share in segmentation and classification, but it will not eliminate handcrafted features; rather, it will make reproducible feature baselines more important, because they serve as the reference for judging whether an end-to-end model has truly learned anything. My assessment is that within twenty-four months, what is more likely to be implemented is a reproducible feature pipeline plus external validation reports, rather than a new paradigm that completely replaces feature engineering.

12. Conclusion: reproducibility is a deliverable, not an appendix

Treating reproducibility as a paragraph in the appendix is why this has never been done well. It is actually part of the deliverable: a dataset that others can rerun, a configuration that others can install back, and a label dictionary that others can verify. Without these three, no matter how good the model is, it is only a one-time demonstration.

For hospital IT departments and radiology departments, the actionable steps are not complex: fix scanning and reconstruction parameters and log changes; write region-of-interest contouring standards into a manual; include data snapshots and experiment configurations in routine archiving. These steps require no new equipment and no new algorithms, yet they determine whether the institution can participate in multicenter research two years from now.

For data teams, the conclusion is equally plain: reproducibility is not an extra cost but the precondition for whether data assets can be reused repeatedly. A dataset that can be explained clearly can be reused by ten projects; one that cannot be explained clearly can support only one paper. Teams across the industry are already beginning to reassess how this calculation should be done.

Langhui's Engineering Capabilities Along This Path

Langhui Technology has focused on AI training data since 2016. In the medical imaging domain, we cover CT, MR, PET, and breast X-ray and ultrasound modalities, designing acquisition standards, performing structured annotation, quality control, and consistency reporting. We build databases stratified by lesion geometry, imaging descriptors, pathological conclusions, and follow-up outcomes, delivering data dictionaries, annotation manuals, and version records so that every sample can be reviewed.

In radiomics-related data projects, we first align fields such as resampling spacing, discretization strategy, and region-of-interest contouring conventions with the algorithm team, then run small-batch trials to compare feature distribution stability under different parameters, and only scale up annotation after the conventions are confirmed. Segmentation quality and feature stability are assessed separately; disagreements go to arbitration and are written back into the manual.

If your team is building a reproducible radiomics dataset, you can send us the modality combinations, scanning protocol ranges, annotation granularity, and acceptance criteria, and we will provide actionable recommendations for acquisition and annotation plans.

FAQ

What is the most common reason radiomics results cannot be reproduced?

The most common reason is that parameters were not fully documented, rather than a problem with the model itself. If any of resampling spacing, interpolation method, gray-level discretization strategy, or gray-level range clipping is missing or differs from the original paper, the feature values will change. Next come inconsistent region-of-interest contouring conventions and information leakage caused by different orders of feature selection and cross-validation. It is recommended to investigate in these three categories first.

Does software that claims to comply with IBSI guarantee reproducibility?

It should not be understood that way. IBSI validates whether feature implementations conform to the definition, usually covering only some feature categories, and does not address acquisition protocols, segmentation conventions, or modeling workflows. Two implementations that both comply with IBSI may produce similar values on the same dataset, but when applied to data from different hospitals they may still be incomparable. It is a ruler, not a certificate of conformity.

Can PyRadiomics default parameters be used directly for publication?

Technically they can produce results, but reproducibility is fragile. Default values change between versions, and the default configuration may not suit your data type and lesion characteristics. A more reliable approach is to explicitly write out the configuration file, pin the version, submit the configuration with the paper or code repository, and explain why this set of parameters was chosen. Merely stating that default parameters were used amounts to no methodological disclosure.

Should gray-level discretization use a fixed number of bins or a fixed bin width?

It depends on the data. Fixed bin width preserves absolute gray-level differences and offers relatively good comparability across devices, making it suitable for multicenter studies with essentially consistent scanning protocols. A fixed number of bins adapts well when lesions span wide gray-level ranges but weakens absolute quantitative information. Whichever is chosen must be reported together with resampling spacing and subjected to stability testing under parameter perturbations.

Can data from different hospitals be pooled directly for modeling?

Direct pooling is not recommended. Differences in devices, reconstruction kernels, slice thickness, and contrast agent regimens introduce inter-batch drift; after pooling, the model may primarily learn center differences. It is recommended to first quantify the drift and then decide whether batch correction is needed; explicitly include multicenter samples in the training set; and retain a fully independent external validation set to determine whether the model has truly learned the signal or merely memorized the source.

References & Further Reading
  1. Image Biomarker Standardisation Initiative (IBSI) official documentation and reference values https://theibsi.github.io/
  2. PyRadiomics official documentation: feature definitions and parameter configuration https://pyradiomics.readthedocs.io/
  3. Zwanenburg A, et al. The Image Biomarker Standardization Initiative: Standardized Quantitative Radiomics for High-Throughput Image-based Phenotyping. Radiology, 2020 https://pubmed.ncbi.nlm.nih.gov/32154773/
  4. van Griethuysen JJM, et al. Computational Radiomics System to Decode the Radiographic Phenotype. Cancer Research, 2017 https://pubmed.ncbi.nlm.nih.gov/29092951/
  5. DICOM Standard official site https://www.dicomstandard.org/
  6. U.S. FDA, Good Machine Learning Practice for Medical Device Development: Guiding Principles https://www.fda.gov/medical-devices/software-medical-device-samd/good-machine-learning-practice-medical-device-development-guiding-principles

FROM INSIGHT TO YOUR PROJECT

Turn Expert Insight into Your Data Solution

Discuss your data needs with Langhui around the technical path and use cases in this article.

Consultation Topic for This Article:Reproducibility of Radiomics Toolchains: IBSI Standards, Feature Drift, and Comparison of Open-Source Tools

Business Phone137-5502-0164Business Emaillk@langhuiai.com
WeChat QR code of Langhui's business contact, scan to add
WeChat

Scan to add a business contact
Or click the QR code to view the original image

View original WeChat contact card

Submit Your Project Requirements

Our business team will reach out during working hours. Fields marked * are required.

* Provide at least one of phone or email.

Do not enter personal medical records, ID numbers, original contract content, or other sensitive information. The title and link of this article are submitted with your request so our business team can understand the context.