ONCOLOGY TRIALS / IMAGING ENDPOINTS
Imaging Endpoint Evaluation in Anticancer New Drug Clinical Trials: Processes and Consistency Challenges
Anticancer new drug trials use imaging as a surrogate endpoint, and the quality of interpretation directly affects whether the data can be accepted. This article starts with the interpretive framework of RECIST 1.1, compares the applicable boundaries of Choi and iRECIST, breaks down the workflow design of independent imaging assessment, reader training and consistency, imaging quality control and audit trails, and explains the appropriate role of AI-assisted interpretation in trial settings, closing with a forward-looking view of the next 12 to 24 months.
Imaging occupies a more prominent position in anticancer new drug trials than many people realize. It is not merely a follow-up record but a surrogate endpoint that underpins efficacy conclusions; if the measurement criteria drift even slightly, the credibility of the entire data chain is compromised. Public statistics show that the proportion of oncology clinical trials relying on imaging assessment has risen from 70 percent to more than 80 percent, bringing with it stricter interpretation rules and more detailed process requirements. This article breaks the assessment process into three stages—acquisition, interpretation, and documentation—and examines stage by stage the boundaries between RECIST and iRECIST, the workflow design of independent assessment, the real-world level of reader consistency, and what auditors actually look at.
I. Why Imaging Became a Surrogate Endpoint for Anticancer New Drugs
The ultimate efficacy of anticancer drugs is defined by survival, but survival takes time. Phase II and some Phase III trials need changes in tumor burden as an early signal, and imaging is that signal source. Public statistics show that roughly 70 percent of 20,000 oncology clinical trials rely on medical imaging for assessment, a proportion that has continued to rise in recent years, reaching close to 80 to 90 percent.
For a surrogate endpoint to hold, the measurements must be reliable. How lesions are selected, how and when they are measured, and who performs the measurement—each step affects the conclusion. What is often questioned in drug review is usually not the statistical methods but the imaging data itself, which fails to tell a clear story: which lesions were selected at baseline, why they were changed mid-study, what the basis for the determination was. If these cannot be answered, the conclusion cannot stand.
There is an easily overlooked distinction here. In clinical practice, the goal of reading images is to be accountable to the patient—report anything suspicious, err on the side of caution. In clinical trials, the goal is to be accountable to the drug—strict adherence to the protocol definitions is mandatory, and grading cannot be raised on one's own just because something looks wrong on the image. The same person will reach different conclusions under these two goals, and this is the first issue that training must address.
As noted in a conference presentation, most of the questions raised during the regulatory review of the marketing application for the first KRAS targeted drug were related to imaging assessment. The significance of such cases lies not in any particular drug, but in demonstrating that imaging is no longer a supporting role: it can determine the fate of a molecule.
II. The RECIST 1.1 Interpretation Framework and Four Common Pitfalls
The framework of RECIST 1.1 is not complicated: at baseline, target lesions are selected—up to two per organ and up to five overall, with lymph nodes measured by short axis; at each follow-up, the sum of the longest diameters is measured and compared with the baseline or the historical nadir; an increase in the sum that reaches the threshold with a sufficient absolute increase is judged as progression; a decrease that reaches the threshold is judged as partial response. The rules are written clearly, yet ambiguity abounds in practice.
The first pitfall is lesion reappearance after disappearance. Reappearance does not equal progression; the lesion must be reintegrated into the total burden calculation, and progression is only declared when the sum grows relative to the nadir and reaches the threshold. Many readers intuitively declare progression on reappearance directly, which is not permitted in trials because it artificially terminates treatment early.
The second is significant overall worsening of non-target lesions. The standard provides no quantitative threshold, so judgment must be based on a combination of findings such as pleural effusion, ascites, and carcinomatous lymphangitis; one or two new nodules alone should not trigger a progression report. The third is the measurement convention for lymph nodes—mixing short and long axes is the most common error, and such errors are difficult to detect during data verification.
The fourth is the handling of special lesions: bone lesions are generally not measurable; cystic lesions require assessment of whether solid components are present; and whether lesions that have received local treatment are included must follow the protocol. All of these are written in the standard text, yet they still go awry in actual interpretation. A workable approach is to make the interpretation logic into a traceable calculation, documenting the measured values, reference baseline, and calculation process at every time point, so discrepancies can be replayed.
III. Choi and iRECIST: The Applicable Boundaries of Two Standards
The Choi criteria target gastrointestinal stromal tumors, using CT density changes in place of size changes alone: a lesion that shrinks by a certain proportion, or whose density falls below a threshold, can be judged as a partial response. The rationale is that such tumors often undergo necrosis rather than shrinkage after treatment, so looking only at size systematically underestimates efficacy. Applying Choi to non-applicable tumor types would misread necrosis as efficacy.
iRECIST addresses pseudoprogression in immunotherapy. It introduces two states, unconfirmed progression and confirmed progression: an initial progression is not immediately declared failure, but must be rechecked and confirmed after a defined window, with both the confirmation window and the calculation of the target lesion sum clearly specified. The cost of this design is that the determination time point is pushed back, increasing the follow-up burden.
Neither standard is a better RECIST; both are supplements targeting specific mechanisms. Mixing them causes problems: using iRECIST in cytotoxic drug trials delays progression determination and dilutes the efficacy signal; using only RECIST in immunotherapy misclassifies pseudoprogression as failure. The standard should be selected according to the mechanism of action at the protocol design stage and stated in the statistical analysis plan.
There is also a practical constraint: once the protocol locks in a standard, it cannot be switched arbitrarily mid-study. When revision is genuinely necessary, the protocol amendment process must be followed, and the switch time point and the handling of data before and after the switch must be explained; otherwise the comparability of the data will be questioned at review. This point is often underestimated until data cleaning, when it becomes irreparable.
IV. Workflow Design for Independent Imaging Assessment
The core of independent imaging assessment is isolating interpretation from the treatment team. Images are read by independent readers according to the protocol, and clinical information is minimized to avoid bias from knowing which drug the patient is receiving. This isolation is not a formality—it determines whether the conclusions will be accepted by regulators.
The workflow typically has two steps: two readers make independent determinations first, with disagreements adjudicated by a third reader. Some protocols adopt a dual-read plus consistency assessment design to support sensitivity analyses. The selection criteria for the adjudicator and what information the adjudicator may see must be spelled out in the charter, or independence is merely nominal.
Time point management is where errors are most likely. Assessment windows, permitted deviation days, and the handling rules for missing time points must all be fixed in the protocol. Examinations outside the window cannot be used casually, as this introduces information bias; when their use is genuinely necessary, they should be reported separately as a sensitivity analysis rather than mixed into the primary analysis.
Independent assessment is not cheap: reader training, reading sessions, adjudication meetings, and data cleaning all require manpower. But from a review perspective, it is the means of turning subjective judgment into verifiable records, and it is virtually indispensable in pivotal registration trials for new drugs. Saving money at this stage usually means spending far more time on explanations later.
V. Reader Training and Consistency
Training does not mean reading the standard aloud once; it means working through a set of cases with reference answers. The training set must cover error-prone scenarios: lymph nodes, cystic lesions, bone lesions, post-treatment cavitation, and pseudoprogression. Each scenario should include several typical and atypical cases so that readers are exposed to disagreements in realistic interpretation.
Consistency is measured by kappa or percentage agreement, but stratified results must be examined. An overall kappa of 0.7 may mask the reality that a particular lesion type has a kappa of only 0.3. A more reasonable approach is to report separately by lesion type, by time point, and by interpretation stage, and to prespecify in the protocol the lower limit of consistency and the handling of non-compliant cases.
Reader qualifications and experience structure should also be recorded. Differences in determination between specialists and general practitioners are systematic, and sponsors need to describe reader composition and conduct sensitivity analyses in the statistics. If readers also participated in protocol design, whether expected bias exists must be explained.
A commonly overlooked practice is retaining readers' original determinations and the reasons for revisions. Revision traces reveal ambiguities in the standard and provide a basis for the next version of the protocol and training materials. A system that keeps only the final conclusion discards the most valuable process information.
VI. Imaging Data Quality Control: From Scan Protocols to Traceability
Quality control starts with scanning. Slice thickness, reconstruction algorithms, contrast agent protocols, and scan phases are difficult to fully standardize across multicenter trials; what a protocol can do is specify minimum requirements—such as upper limits on slice thickness, required phases, and coverage—and require each site to submit actual parameters. Without parameter records, later analysis cannot determine whether differences stem from treatment or from equipment.
The transmission and storage stages must ensure that raw data is not overwritten. DICOM metadata is the foundation of traceability: patient identifiers, examination time, device model, and series number must be complete, and any anonymization must retain a mapping table. The mapping table itself must have access controls—this is the baseline of compliance, not an option.
Image quality determination should be front-loaded. Respiratory motion artifacts, contrast extravasation, phase errors, and incomplete coverage—these can be rescanned if caught on the day of acquisition, but if discovered at the analysis stage they can only become missing data. Front-loaded determination requires someone to own it, typically the site imaging coordinator, rather than leaving readers to raise issues ad hoc during interpretation.
It is recommended that a per-case quality checklist be established: scan parameter compliance, completeness of phases, coverage, artifact grading, and presence of measurable lesions. Once checklist-based, both missing rates and rescan rates can be tallied, and site operating habits can be constrained in reverse. This is far more effective than holding meetings after the fact to emphasize quality.
VII. Audit Trails: What Auditors Look For
Audits focus on whether a conclusion can be reconstructed. Given an efficacy determination at a point in time, an auditor must be able to see the original images, measurement records, reader forms, adjudication records, and protocol version. If any link is missing, the evidence chain is broken and the determination can only count as personal opinion.
A common deficiency is that measurement records exist only in the reading system, with no version or timestamp after export; or that the adjudication process has conclusions without reasons. Such deficiencies will require supplementary explanations during data verification and, in serious cases, affect the acceptability of the entire data set. Retroactive record-keeping is often far more expensive than writing one extra line of explanation in the first place.
Digitized systems can alleviate but not replace process. A system can record who changed which value and when, but if the protocol does not define modification permissions and review steps, the system record is merely an operation log, not an auditable evidence chain. What a tool can do is formalize a process—it cannot design the process for you.
The granularity of documentation should match the risk. Every determination of a key endpoint such as a progression-free survival event should be fully documented; documentation for secondary endpoints can be simplified. Concentrating resources on the stages that will be scrutinized at review is the more practical approach, and it is also easier to sustain over time with limited staff.
VIII. The Role of AI-Assisted Interpretation in Trial Settings
The appropriate role of AI in trials is to assist with measurement and consistency checks, not to replace readers in making determinations. Automated segmentation and long-axis measurement can reduce human error, with clear value especially in trials involving many lesions and many time points. Time saved on measurement can be redirected toward discussing discrepancies and reviewing difficult cases.
However, AI outputs must be verifiable. When a model produces a number, the reader must be able to see the boundaries it delineated and modify them; only the modified result becomes the basis for determination. Black-box outputs cannot enter the audit chain because they cannot answer the question of where the number came from.
Another use case is anomaly screening: automatically flagging possible new lesions, phase errors, and substandard image quality, directing human attention to what needs review. Such applications do not directly produce determinations, carry lower risk, and deploy faster—they are the more realistic entry point at present.
What warrants caution is treating AI consistency as the gold standard. A model may be consistent within its training distribution but systematically drift outside it; if a protocol uses it as a reference, the version, training data scope, and validation results must be specified. Otherwise, an untested set of biases is effectively written into the process, and it is very difficult to detect afterward.
IX. Handling Common Controversies and Disagreements in Determination
The three most contentious categories are: whether a new lesion constitutes progression, how changes in lesions that have received local treatment should be counted, and whether worsening symptoms can serve as an independent basis for determination. If the protocol contains no explicit rules, each site will handle matters according to its own habits, eventually surfacing during data aggregation as unexplainable variability.
The principle for resolving disagreements is to consult the protocol first, then the standard, and finally the adjudication. The protocol takes priority because it has been tailored to this specific trial; the standard provides a general framework; and the adjudication mechanism addresses situations neither of the first two can cover. Reverse the order and general standards will override protocol agreements—a clear problem at review.
Controversies are themselves valuable data. Classifying the cause of each disagreement—ambiguous definitions, image quality, reader experience, insufficient information—can, once accumulated in sufficient quantity, feed back into revisions of training materials and protocol templates. Most teams record only the conclusion and not the reason, forfeiting a free opportunity for quality improvement.
For sponsors, it is advisable to establish a disagreement register early in the trial rather than reconstructing it at the data cleaning stage. Problems found early can be corrected; those found late can only be explained. Explanation costs far more than correction, and explanations are often not accepted.
X. A Forward-Looking View for the Next 12 to 24 Months
First, process standards for imaging endpoints will receive greater emphasis. Regulatory focus on imaging data is shifting from whether results are reasonable to whether the process is verifiable, and standardized documents for imaging acquisition and interpretation will become routine attachments in submissions. By then, trials lacking process documentation will be noticeably disadvantaged, even if the conclusions themselves are sound.
Second, submission pathways for AI-assisted tools will diverge. Measurement-assistance and quality control tools carry lower risk and will deploy faster; tools that assist efficacy determination require prospective validation and longer observation periods and will have difficulty entering key endpoint determination in the short term. Companies that benchmark directly against determination from the outset are likely to get stuck on evidence requirements.
Third, domestically led multicenter trials will drive refinement of local workflows. Public statistics show that China's share of global anticancer drug clinical trials has risen from single digits a decade ago to nearly 40 percent, bringing with it higher requirements for assessment consistency. There is a strong likelihood that industry-level assessment guidelines will be updated within the next two years, with emphasis on imaging quality control and reader consistency.
The earliest beneficiaries will be institutions that have already established independent reading teams and imaging data management platforms. They can get involved at the protocol design stage, writing assessability requirements, scanning requirements, and interpretation rules into the protocol rather than patching things during data cleaning. Such capabilities do not appear on equipment lists, yet they directly determine whether a trial can be completed.
XI. Conclusion: Treat Assessment as a Data Production Line
Imaging endpoint evaluation looks like reading work, but it is in substance a data production line: acquisition, transmission, quality control, interpretation, documentation, and delivery. The output of every stage must be usable downstream and traceable by audit. Designing this line as a whole is more effective than piling manpower onto any single stage.
For hospitals, the value of participating in trials lies not just in the number of projects, but in whether they can build a reusable workflow and team. Once the process is stable, the same investment can support more trials and, in turn, feed back into the data quality of clinical research. Conversely, relying on ad hoc staff deployment to handle projects yields roughly the same accumulation whether you do ten trials or one.
For sponsors, what to evaluate when selecting sites is process capability rather than equipment lists: whether there is an independent reading mechanism, whether there is a quality checklist, whether there is a documentation system. These invisible elements often determine the success or failure of pivotal trials—and whether imaging data can ultimately support a conclusion.
Langhui's Engineering Capabilities Along This Path
Langhui Technology has focused on AI training data since 2016. In medical imaging, we cover acquisition protocol design, structured annotation, quality control, and consistency reporting across CT, MR, PET, and breast X-ray and ultrasound modalities. We build databases stratified by lesion geometry, measurement diameter, imaging descriptors, and follow-up conclusions, delivering data dictionaries, annotation manuals, and version records so that every sample can be reviewed.
On imaging assessment-related data projects, we first align lesion selection rules, measurement conventions, time point windows, and determination standards with clinicians, then conduct small-batch dual annotation, calculate consistency separately by lesion type and time point, route disagreements to arbitration, and scale up only after revising the manual. We are responsible for verifying metadata and flagging missing data in original images; determination conclusions are issued by qualified reading parties.
If your team is preparing imaging data management, independent reading support, or historical data cleaning for an anticancer new drug trial, you can send us the tumor type, standard version, assessment time points, and number of sites, and we will provide actionable recommendations for acquisition and quality control plans.
FAQ
Under RECIST 1.1, does a lesion that disappears and then reappears count as progression?
Not necessarily. A reappearing lesion must be reintegrated into the total burden calculation, and progression is declared only when the sum grows relative to the historical nadir and reaches the threshold agreed in the protocol. Treating reappearance directly as progression artificially terminates treatment early—it is a common error in trial interpretation and a point that is easily raised during audits.
Can iRECIST and RECIST 1.1 be used interchangeably?
It is not recommended. iRECIST was designed for immunotherapy and introduces unconfirmed progression and a confirmation window; using it in cytotoxic drug trials delays progression determination and dilutes the efficacy signal. The protocol should select the standard according to the mechanism of action at the design stage; any mid-study switch requires the protocol amendment process and an explanation of data handling.
Must all anticancer trials conduct independent imaging assessment?
Not all, but pivotal registration trials usually require it. The value of independent assessment lies in isolating interpretation from the treatment team, reducing information bias, and leaving verifiable records. Early exploratory trials focused mainly on safety may simplify, but the protocol must state the rationale and the alternative quality control measures.
What materials are generally examined in an imaging assessment audit?
The main question is whether the conclusion can be reconstructed: original images, measurement records, reader forms, adjudication records, protocol version, and timestamps. Common deficiencies are measurements that exist only in a system and cannot be exported, or adjudications with conclusions but no reasons. It is recommended that every determination of a key endpoint be fully documented; secondary endpoints can be appropriately simplified.
Can AI automatic measurement be used directly for clinical trial determination?
Not as a direct replacement at present. The appropriate use is to assist with measurement and quality screening; outputs must be verifiable and modifiable, and only the result confirmed by the reader becomes the basis for determination. If a protocol uses AI as a reference, the version, training data scope, and validation results must be specified, or it will struggle to pass audit and review.
- Eisenhauer EA, et al. New response evaluation criteria in solid tumours: revised RECIST guideline (version 1.1). European Journal of Cancer, 2009 https://doi.org/10.1016/j.ejca.2008.10.026
- Seymour L, et al. iRECIST: guidelines for response criteria for use in trials testing immunotherapeutics. The Lancet Oncology, 2017 https://doi.org/10.1016/S1470-2045(17)30074-8
- Choi H, et al. Correlation of computed tomography and positron emission tomography in patients with metastatic gastrointestinal stromal tumor treated at a single institution with imatinib mesylate. Journal of Clinical Oncology, 2007 https://doi.org/10.1200/JCO.2006.09.9228
- U.S. FDA, Clinical Trial Imaging Endpoint Process Standards: Guidance for Industry https://www.fda.gov/regulatory-information/search-fda-guidance-documents/clinical-trial-imaging-endpoint-process-standards-guidance-industry
- DICOM Standard, 医学影像数据交换与元数据规范 https://www.dicomstandard.org/
- U.S. FDA, Good Machine Learning Practice for Medical Device Development: Guiding Principles https://www.fda.gov/medical-devices/software-medical-device-samd/good-machine-learning-practice-medical-device-development-guiding-principles