Langhui

MASLD / AI IN CHRONIC LIVER CARE

AI in the management of metabolic dysfunction-associated steatotic liver disease: quantification, stratification and long-term follow-up

The population with metabolic dysfunction-associated steatotic liver disease is large and highly heterogeneous, with patients scattered across endocrinology, health check-ups and primary care. The value of AI lies not in replacing diagnosis, but in linking fat quantification by ultrasound and MRI-PDFF, fibrosis stratification by FIB-4 and elastography, and long-term follow-up data into an actionable pathway. This article discusses quantification methods, stratification thresholds, patient identification, follow-up data and the boundaries of digital pathology, and offers a 12- to 24-month outlook.

Healthcare and healthRecherche sectorielle de Langhui · Synthèse d'échanges R&D

Metabolic dysfunction-associated steatotic liver disease (MASLD) is currently the most heterogeneous category of liver disease and requires the greatest degree of interdisciplinary collaboration. Most patients do not enter hepatology at the outset; instead, they are recorded in fragmented ways during health check-ups, in endocrinology, cardiology or community health centers. The role of AI along this pathway is not to make diagnoses for physicians, but to integrate scattered data into actionable triage: who needs further quantification, whose fibrosis risk requires specialist assessment, and who can remain in primary-care follow-up. This article proceeds through six stages—fat quantification, fibrosis stratification, risk triage, patient identification, long-term follow-up and digital pathology—explaining the available tools at each step, threshold pitfalls and the limits of the evidence.

1. The challenge is not diagnosis, but separating the population

The diagnosis of fatty liver itself is not especially complex: imaging shows fat deposition, other causes are excluded, and in most cases the diagnosis can be established. The real difficulty is stratification: the same ultrasound report of “moderate fatty liver” may reflect simple fat deposition or metabolic dysfunction-associated steatohepatitis in which fibrosis has already developed, and the management pathways for the two are completely different. Public estimates suggest that about three in ten adults worldwide have fatty liver disease. The size of this population means that it is impossible to perform a full assessment on everyone; stratifying first and then deciding the depth of testing is the more realistic strategy.

The heterogeneity of this disease manifests in several directions. Some patients are dominated by obesity and insulin resistance, others have normal body weight but abnormal metabolic markers, and others also have alcohol-related factors that need to be distinguished from metabolic causes. The 2023 international consensus introduced a specific category for coexisting metabolic and alcohol-related factors. Progression rates, spectra of complications and intervention priorities differ across subtypes; using a single uniform label to manage them can easily leave high-risk patients in low-risk follow-up cohorts.

Patients are also widely dispersed. Health check-up centers detect fatty liver, endocrinology manages blood glucose, cardiology manages blood pressure and lipids, weight-management clinics manage body weight, and community health centers conduct chronic-disease follow-up. The patients seen by hepatology are often only the small fraction already referred onward. Data are scattered across different systems, test panels and follow-up intervals vary, and no one can see a patient's complete trajectory. This is precisely where AI can intervene, but the form of intervention is integration and prompting—not replacing any physician's conclusion.

There is another easily overlooked fact: the leading cause of death in this disease is usually not the liver, and cardiovascular events account for a large share. This means that risk stratification cannot focus only on liver fibrosis; it must also consider blood pressure, lipids, blood glucose and renal function. A model that only outputs a “probability of liver fibrosis” cannot answer the questions clinicians truly care about. A tool that can provide both liver and cardiovascular risk signals is closer to a usable form.

Diagram of routes for quantifying intrahepatic fat: abdominal ultrasound screening, controlled attenuation parameter and attenuation imaging in quantitative ultrasound, MRI-PDFF proton density fat fraction, thresholds and phantom calibration, association with metabolic markers, and follow-up re-measurement
Fig.1 Screening depends on accessibility, confirmation on repeatability: threshold calibration when the two routes connect determines whether longitudinal data can be compared.

2. Fat quantification: ultrasound as a coarse screen and MRI-PDFF as the yardstick

Abdominal ultrasound is the most widely available entry point: inexpensive, radiation-free and accessible, making it suitable for initial screening. Its interpretation, however, is clearly subjective. Sensitivity for mild fat deposition is limited and is affected by operator experience, patient body habitus and subcutaneous fat thickness. Reports commonly use three grades—mild, moderate and severe—with no standardized cut-offs between them. As a yes-or-no screening tool it is sufficient; as a tool for measuring how much has changed during follow-up it is not.

Quantitative ultrasound attempts to fill this gap. Controlled attenuation parameter, attenuation imaging and the liver-to-kidney echo ratio convert differences in echogenicity into numerical values; the equipment is widely available and examinations are short. The trade-off is that the metrics are influenced by body-mass index, subcutaneous fat, equipment and probe, algorithms differ across vendors, and thresholds must be localized. Re-measuring the same patient on a different machine can produce a noticeable shift in values, which is a serious problem for longitudinal follow-up.

MRI-PDFF is currently recognized as a relatively stable quantitative reference. Based on chemical-shift encoding, it measures proton density fat fraction, correlates well with biopsy fat content and has high repeatability, making it suitable for before-and-after comparisons. Its limitations are also real: access to equipment and sequences is limited, scan time and cost are higher than with ultrasound, and it is unsuitable for patients with metallic implants or claustrophobia. It is better suited as a yardstick for confirmation and follow-up stages than as a population screening method.

The key to connecting these approaches lies in thresholds and calibration. The industry commonly uses a threshold of around 5% for steatosis, but values obtained with different vendors and sequences differ systematically; phantom calibration or at least a consistency assessment should be performed before cross-center comparisons. One point must be emphasized repeatedly: PDFF reflects only fat content, not fibrosis. A decline in fat fraction does not equal reversal of fibrosis. Conflating the two is the most common source of misunderstanding in patient communication.

Diagram of the fibrosis stratification chain: FIB-4 screening, grey-zone identification, elastography refinement, second-line markers, stratification conclusion, and referral and follow-up arrangements
Fig.2 Stratification cannot be settled by a single laboratory test: FIB-4 screens, elastography refines, and the grey zone requires combined markers and a clear next step.

3. Fibrosis stratification: start with FIB-4, refine with elastography

FIB-4 is the most economical starting point. Calculated from age, aspartate aminotransferase, alanine aminotransferase and platelet count, it can be computed in batches from existing laboratory data without additional testing. The usual practice is to set two cut-offs: values below the lower limit are considered low risk, values above the upper limit high risk, and values in between indeterminate. Its value lies in keeping a large number of low-risk patients away from further testing and reserving limited elastography and specialist resources for those who need them more.

The limitations of FIB-4 are equally clear. Age carries substantial weight in the formula, so older patients are easily pushed into the high-risk range; acute inflammation, hemolysis and platelet abnormalities can all distort the result; and its ability to discriminate within the intermediate range is particularly limited. It is a screening tool, not a diagnostic tool, and it cannot by itself determine whether treatment is needed. Interpreting it as a “laboratory marker of liver fibrosis” is a fairly common clinical error.

Elastography provides information in another dimension. Vibration-controlled transient elastography measures liver stiffness; two-dimensional shear wave elastography can be performed on conventional ultrasound equipment; magnetic resonance elastography is more precise but limited by cost and availability. Stiffness values are affected by inflammation, congestion, fasting state, operator technique and probe position, and thresholds differ by etiology. Whether the patient fasted before the examination and whether right-heart dysfunction is present will change the readings; if these conditions are not recorded, the values cannot be interpreted.

Where AI is genuinely needed is the uncertain middle range. Most patients are neither clearly low risk nor clearly high risk, but fall into a grey zone. A feasible approach is to combine FIB-4, elastography, platelets, transaminases, metabolic markers and even image texture into a continuous risk estimate, together with recommended next-step tests. The goal is not to eliminate the grey zone, but to subdivide the people within it so that those who need referral are referred and those who need follow-up are followed up, avoiding an immediate jump to invasive testing.

4. The output of risk stratification should be routing advice

Stratification should cover at least three dimensions: liver fibrosis risk, cardiometabolic risk and extrahepatic complication risk. Fibrosis determines whether specialist assessment and treatment considerations are needed; cardiovascular risk determines the intensity of blood-pressure, lipid and glucose management; extrahepatic risk includes declining renal function, sleep apnea and certain cancer risks, and determines the follow-up schedule. If only one dimension is scored, physicians must fill in the other two themselves, and the value of the tool is negated.

The recommended output format is routing advice, not a diagnostic label. The three common categories are: remain in primary-care follow-up, refer to a specialist for further assessment, and enter structured intervention or a clinical trial. Each category should specify its trigger conditions and confirmation pathway—for example, “repeat liver function tests and elastography within three months,” rather than a vague “recommend specialist consultation.” Triage without a confirmation pathway eventually leads patients to search on their own or simply not go.

Threshold settings must reflect institutional capacity. Tertiary hospitals can tolerate a higher false-positive rate because they have ample resources for review; primary-care health centers need a high negative predictive value to avoid referring large numbers of healthy people. When the same model is used across different levels of care, cut-offs should be configurable and calibrated on local data. When comparing two models, calibration curves are more decision-relevant than the area under the curve—a point that is especially pronounced in risk-stratification scenarios.

Communication cannot be skipped. A risk score is not a diagnosis; patients who see “high risk” may easily interpret it as already being ill, while those who see “low risk” may relax completely. It is advisable to present only the stratification conclusion and next action to the patient, leaving specific probabilities to the physician interface, while clearly explaining that the score changes with body weight and metabolic markers and that repeat testing is meaningful. Translating a tool's output into language patients can understand without being misled is itself part of the design.

5. Patient identification: the data is scattered across departments

To identify patients, one must first acknowledge where the data are. Abdominal ultrasound and liver enzymes from health check-up reports, blood glucose, HbA1c and medication records from endocrinology, lipids and antihypertensive regimens from cardiology, weight and waist circumference from weight-management clinics, and chronic-disease follow-up forms from primary care must be assembled to outline a person's metabolic profile. Looking only at hepatology data reveals only the portion already referred.

A feasible approach combines rule-based recall with model-based ranking. First use deterministic rules to identify people who clearly need attention—persistent elevation of liver enzymes, a high body-mass index with diabetes, or a fatty-liver description in an imaging report. Then use a model to rank the candidate population, placing those most likely to need further evaluation first. Rules ensure nothing is missed; the model handles ranking. Combining the two is easier to explain than relying on a single model alone and is also more readily accepted in clinical practice.

Recall must be followed by a confirmation pathway. If a flagged person merely receives a reminder without a plan for repeat testing, the result is often a period of anxiety followed by inaction—or the patient independently undergoes a pile of unnecessary tests. A sensible pathway is: reminder → primary-care repeat liver function tests and ultrasound → those still abnormal are referred upward for elastography or quantitative imaging → specialist care when needed. Every step needs an accountable owner, otherwise recall is only a one-off action.

Data boundaries should be established in advance. Analyses that can be completed within the institution should not be shared externally; when sharing is necessary, de-identification and access auditing are required, and cross-institutional use must have clear authorization and defined purposes. Patient identification involves a large amount of retrospective data, so compliance issues often arise before algorithmic issues. Recording data dictionaries, field sources and update frequencies supports both model reproducibility and the ability to state during an audit which record each conclusion came from.

6. Long-term follow-up: complete data matters more than a smart model

The core variables for follow-up are not complex: body weight, waist circumference, liver enzymes, lipids, blood glucose and HbA1c, fat-quantification markers and liver stiffness. Intervals are set according to risk stratification; low-risk patients can be reviewed annually, while intermediate- and high-risk patients are shortened to three to six months. The real challenge is collecting these variables consistently and keeping the measurement basis the same each time. If the equipment, test package or recording method changes, the trend line breaks.

Loss to follow-up is the greatest enemy. Attrition in follow-up for metabolic chronic diseases is high; patients simply stop coming when they feel no symptoms. What a system can do is send reminders, align test panels, and flag missing data and their reasons, so that at the next visit the physician knows which data are absent. These tasks may not sound intelligent, but they improve follow-up quality more than retraining another model. AI's role in this chain is to reduce friction, not to change patients' habits for them.

Evaluation of intervention effects should be cautious. Public guidelines note that a weight reduction of about one tenth is associated with improved liver fibrosis, and a reduction of about five percent can improve intrahepatic fat content. Such conclusions come from population studies and cannot be applied directly to individuals—still less can they be inverted to conclude that “if fat content has not decreased, the intervention was ineffective.” Turning correlation into causation in reports is the most common way these tools overstep their bounds.

Patient-facing tools should be restrained. A simple self-assessment score can prompt people to seek testing, but it can also produce two side effects: excessive anxiety in those with high scores and false reassurance in those with low scores. A more prudent design performs only risk stratification and care navigation, explicitly states “this is not a diagnosis,” and indicates where to go next. Building this boundary into the product is more effective than putting it on the last line of an instruction manual.

7. Digital pathology and drug development: what has already changed

In drug development, digital pathology is currently the most firmly established area. Trials of metabolic dysfunction-associated steatohepatitis rely on histological scoring of liver tissue, but the scores themselves vary between readers; different experts may assign different grades of inflammation or fibrosis to the same slide. AI-assisted central reading reduces this variation through standardized segmentation and grading and has been used in pathology assessment processes for some registration trials. It is also one of the few AI applications in this field that has truly entered the decision chain.

More research value lies in continuous quantification. Traditional scoring divides fibrosis into several grades, compressing the information between them; image analysis that yields continuous measures such as the proportion of fibrotic area, proportion of fatty area and inflammatory-cell density can reflect changes before and after treatment more sensitively. These measures are currently used mainly for mechanistic research and trial exploration; whether they can serve as registration endpoints still requires communication with regulators and accumulation of evidence.

Other parts of drug development are also changing. Target discovery, molecular optimization, inclusion and exclusion criteria for trial design, and site selection all use data-driven methods. New treatment options have emerged in the metabolic field in recent years, including glucagon-like peptide therapies and thyroid-hormone-receptor agonists targeting the liver. As access to these drugs improves, demand for screening and follow-up will rise. Whoever can reliably “find the right patients” will be able to absorb this demand.

The role of imaging biomarkers needs to be stated clearly. Proton density fat fraction has been used in some trials as a surrogate marker of changes in fat content, but it cannot replace histology and hard endpoints. Treating a surrogate endpoint as efficacy itself is a mistake easy to make in both development and clinical practice. The value of a tool is to shorten trial cycles and select the right population—not to move conclusions forward in time.

8. Engineering boundaries of the agent

Agents designed for liver-disease management are usually built around four interfaces: a screening interface for primary care and health check-up settings, a physician interface for specialists and generalists, a management interface for follow-up scheduling and quality control, and a patient interface for explanations and reminders. The four interfaces share one knowledge base but differ in permissions and output granularity. The primary-care interface should not see details requiring specialist judgment, and the patient interface should not see probabilities that may cause misunderstanding; this layered design is a prerequisite.

Architecturally, rules, models and retrieval should be used in combination rather than delegating all judgment to a single large model. Rules handle deterministic triage conditions, models handle ranking and risk estimation, and retrieval pulls guideline text and local pathways for physician verification. Outputs must be traceable: which laboratory test, which imaging study or which version of a guideline a conclusion came from. The physician interface must include a review checkpoint; the final words spoken to the patient are confirmed by the physician, with the system offering suggestions only.

Knowledge updates and localization are ongoing work. Guidelines change, drugs change, and the institution's test panels and referral channels differ. The system needs a versioned knowledge base and configurable local pathways, with changes logged and users notified. On data security, processing should occur within the institution wherever possible; cross-institutional calls require authorization and audit, and logs must be able to answer “who looked at what, and when.”

The boundaries must be fixed: no diagnosis, no prescribing, no replacement for emergency judgment. When warning symptoms, clearly abnormal liver function or suspected acute illness appear, the system should directly recommend seeking medical care instead of continuing the risk-stratification workflow. Writing “when it should not be used” into product rules is more important than making “what it can do” sound impressive; this is also the key to whether such tools can remain in clinical practice over the long term.

9. Barriers to deployment: data, workflows and evidence

Data-related barriers are the most direct. Ultrasound reports are mostly free text with inconsistent descriptive terms; test panels differ across institutions, as do units and reference ranges; imaging data are scattered across PACS and health check-up systems, and retrieval requires approval. To perform stratification, these fields must first be structured—and that structure is itself a long-term investment that a single project cycle can rarely complete.

Workflow barriers are often underestimated. Who executes recall, who is responsible for review, whether referral channels are open, and where the additional workload is recorded—unless these questions are resolved, a tool will remain at the demonstration stage after launch. Primary-care physicians are already short-staffed; if a system merely adds more to-do items without reducing other work, adoption will quickly fall. Design should minimize new actions, ideally embedding them into existing follow-up workflows.

Evidence barriers arise from endpoint selection. The gold standard for liver fibrosis is histology, but it is invasive, subject to sampling error and poorly accepted by patients; hard endpoints such as decompensated cirrhosis and death require long follow-up and large sample sizes. Most AI research stops at surrogate markers and retrospective data, and prospective studies capable of answering outcome questions are rare. This determines that, in the short term, such tools are better positioned as adjuncts to stratification rather than as judges of efficacy.

Organizational barriers are the old problem. Collaboration among endocrinology, hepatology, cardiology and primary care requires clear points of contact, and assessment and incentives must keep pace; otherwise multidisciplinary consultation easily becomes a one-off event. What AI can provide is data and reminders; cross-departmental trust must be built through people and processes. Only by thinking this through clearly can one avoid attributing deployment failures to an insufficiently good model.

10. Outlook for the next 12 to 24 months

First, nomenclature and measurement conventions will continue to converge. After metabolic dysfunction-associated steatotic liver disease and its coexisting categories were written into international consensus, data fields, diagnostic codes and follow-up indicators across organizations will gradually align, creating conditions for cross-institutional data integration. Consistent conventions are a prerequisite for AI to work; progress in this area over the next two years will merit more attention than model advances.

Second, combined noninvasive testing pathways will move downstream. The stratification approach that starts with FIB-4, refines with elastography and adds second-line markers when necessary will appear more often in primary-care chronic-disease management pathways. This will bring demand for training on “who can perform elastography and how should results be interpreted”; AI can take on quality control and prompts in this area, rather than replacing the operators.

Third, improved access to drugs will change the structure of demand. Once new treatments enter clinical use, the population needing identification, assessment and follow-up will expand, increasing the pressure of screening and adherence management. This is an opportunity for systems that integrate laboratory, imaging and follow-up data, while offering limited help to models that only perform single-point classification.

Fourth, penetration of quantitative imaging will accelerate but remain constrained by resources. Proton density fat fraction and MR elastography will become more established in trials and specialist centers; the value of AI will first appear in measurement consistency, quality control and structured reporting. Those to benefit earliest are institutions and regional platforms that already have structured laboratory data, imaging data and stable follow-up cohorts.

11. Conclusion: put AI in the workflow, not on the report

Managing metabolic dysfunction-associated steatotic liver disease is essentially a long chain: identification, quantification, stratification, referral, intervention and follow-up. AI can contribute something at every stage, but no stage can be handed over to it completely. Placed in the workflow, its value is reducing omissions, duplication and inconsistent conventions; placed on the report, it becomes merely an attractive extra paragraph that is forgotten once read.

For hospitals, a more realistic goal is not full end-to-end intelligence in one step, but first making one or two stages solid—for example, connecting health check-up ultrasound and liver-enzyme data for recall, or turning FIB-4 and elastography results into an interpretable stratification card. These tasks do not require the most advanced model, but they do require data governance and process alignment, and once completed they can run for a long time.

For technology teams, one fact must be accepted: endpoints in this disease arrive slowly and evidence is hard to accumulate. What can often be demonstrated are process and surrogate indicators; what should be stated clearly is that the system is traceable, auditable and reversible. Explaining the boundaries clearly is easier than overselling capabilities, and it is what earns long-term clinical trust.

L'expertise d'ingénierie de Langhui sur ce parcours

Langhui has focused on AI training data since 2016, covering CT, MR, PET, mammography, ultrasound and other modalities in medical imaging. We design acquisition specifications, perform structured annotation, quality control and consistency reporting: breaking imaging descriptions, measurements and follow-up conclusions into verifiable fields, and delivering data dictionaries, annotation manuals and version records so that every sample can be reviewed.

In data projects related to metabolic and chronic diseases, we first align stratification conventions, gold-standard sources and follow-up milestones with clinical teams, then perform small-batch double annotation, calculate consistency by modality and device, route disagreements to arbitration, and scale up after revising the manual. Verification of original imaging metadata and marking of missing data are our responsibility. We should be clear that we do not claim the platform has complete capabilities for endoscopy, whole-slide pathology or medical-record text processing, nor do we claim any certification; when these areas are involved, we explicitly mark them as collaborative or outsourced scope.

If your team is preparing fatty-liver cohort data curation, quantitative imaging annotation or structuring of follow-up data, you can send us the modalities, examination items, follow-up intervals and field list. We will provide actionable recommendations for acquisition and quality control, and explain which judgments require joint confirmation by clinical and statistical teams.

Questions fréquentes (FAQ)

Abdominal ultrasound at a health check-up suggests fatty liver—do I still need MRI-PDFF?

Not necessarily. First check for metabolic risk factors and abnormal liver enzymes, then use FIB-4 for initial screening. Low-risk patients can remain in primary-care follow-up; only those whose FIB-4 falls into the indeterminate range or whose elastography is elevated should be considered for confirmation with quantitative imaging. MRI-PDFF has the advantage of good repeatability and is suitable for before-and-after comparisons, but its availability and cost limit its use as a population screening method.

Does a high FIB-4 mean liver fibrosis is present?

It should not be interpreted that way. FIB-4 is a screening tool; age, acute inflammation, hemolysis and platelet abnormalities can all raise the value, and its discrimination within the intermediate range is limited. The correct use is to set upper and lower cut-offs: low values rule out, high values trigger referral, and intermediate values lead to elastography or second-line marker assessment. A single elevated result should be interpreted alongside imaging and follow-up rather than used to draw an immediate conclusion.

What factors affect liver stiffness values measured by elastography?

Inflammatory activity, hepatic congestion caused by right-heart dysfunction, fasting state, operator technique and probe position all change the readings, and thresholds differ by etiology. Whether the patient fasted beforehand and whether ascites or obesity is present must also be recorded. Without this contextual information, a single stiffness value is difficult to interpret and is even less suitable for direct comparison across devices.

Can AI directly decide whether a fatty liver patient should take medication?

Not at present. What AI can do is risk stratification and routing advice—for example, indicating who needs further fibrosis assessment and who needs intervention for cardiovascular risk. Whether medication is needed involves histology, metabolic markers, comorbidities and drug access, and must be decided by a physician. Treating a tool's output as a basis for prescribing goes beyond the boundaries of the evidence and is inconsistent with how responsibility is assigned.

How can AI help with follow-up for metabolic dysfunction-associated steatotic liver disease?

Mainly in three areas: reminding patients of follow-up timing and tests, keeping the measurement basis of each examination consistent, and flagging missing data and their reasons. These tasks are not flashy, but they can significantly improve follow-up completeness. Whether a patient can lose weight or maintain exercise depends on the intervention plan and support system; tools can only reduce friction and cannot replace behavior change.

Références et lectures complémentaires
  1. European Association for the Study of the Liver (EASL), AASLD, EASO. Clinical Practice Guidelines on the management of metabolic dysfunction-associated steatotic liver disease (MASLD). Journal of Hepatology, 2024 https://doi.org/10.1016/j.jhep.2024.04.031
  2. Rinella ME, et al. A multisociety Delphi consensus statement on new fatty liver disease nomenclature. Hepatology, 2023 https://doi.org/10.1097/HEP.0000000000000520
  3. Sterling RK, et al. Development of a simple noninvasive index to predict significant fibrosis in patients with HIV/HCV coinfection. Hepatology, 2006 https://doi.org/10.1002/hep.21178
  4. Castera L, Friedrich-Rust M, Loomba R. Noninvasive Assessment of Liver Disease in Patients With Nonalcoholic Fatty Liver Disease. Gastroenterology, 2019 https://doi.org/10.1053/j.gastro.2018.12.036
  5. U.S. FDA. Noncirrhotic Nonalcoholic Steatohepatitis With Liver Fibrosis: Developing Drugs for Treatment https://www.fda.gov/regulatory-information/search-fda-guidance-documents/noncirrhotic-nonalcoholic-steatohepatitis-nash-liver-fibrosis-developing-drugs-treatment
  6. World Health Organization. Obesity and overweight — fact sheet https://www.who.int/news-room/fact-sheets/detail/obesity-and-overweight

FROM INSIGHT TO YOUR PROJECT

Faites de l'expertise votre solution data

Échangez avec Langhui sur vos besoins data autour du parcours technique et des cas d'usage présentés dans cet article.

Sujet de la demande :AI in the management of metabolic dysfunction-associated steatotic liver disease: quantification, stratification and long-term follow-up

Téléphone commercial137-5502-0164E-mail commerciallk@langhuiai.com
Code QR WeChat du contact commercial de Langhui, scannez pour l'ajouter
Contact WeChat

Scannez pour ajouter votre contact commercial
Ou cliquez sur le code pour voir l'image originale

Voir la carte de contact WeChat d'origine

Soumettez votre besoin projet

Notre équipe commerciale vous contactera pendant les heures ouvrées. Les champs marqués d'un * sont obligatoires.

* Renseignez au moins un numéro de téléphone ou un e-mail.

N'indiquez pas de dossier médical, numéro d'identité, contenu de contrat ou autre information sensible. Le titre et le lien de cet article seront transmis avec votre demande afin de faciliter la compréhension du contexte par notre équipe.